VFD185CP43B-21

Subscribe to get prices

Model: VFD185CP43B-21

Order No: DELTA VFD185CP43B-21

SKU: 10000037290101

Condition: New Sealed Under Guarantee

Size: 32.00 cm,52.00 cm,31.00 cm

Weight: 7.00kg

Product Selection Engineer:ZhangWenBing

In Stock

Brief Introduction

VFD185CP43B-21

Input Power (V) 460V 3-Phase Output Current (A) 38.00 Control methods IMVF ; IMSVC (Space Vector Control) ; PMSVC Built-in EMC filter No Built-in DC reactance No Built-in brake crystal Yes Motor Power (kW) 18.50 Degree of protection IP20/UL Open Type ; IP20/UL Type1/NEMA1 version Wall Mount Safe Torque Off (STO) Yes Motor type Induction Motor(IM) ; Interior Permanent Magnet Motor(IPM) ; Surface Permanent Magnet Motor(SPM) ; PMA-SynRM Numeric Inputs (points) 8 Digital Outputs (Points) 0 Relay Outputs (points) 3 Analog Input 0~10V (points) 2 Analog Input: -10~10V (points) 0 Analog Input 0~20mA (points) 0 Analog Input: 4~20mA (points) 1 Analog output 0~10V (points) 1 Analog output -10~10V (points) 0 Analog output: 0~20mA (points) 0 Analog output: 4~20mA (points) 1 Degree of contamination 2 Humidity (%) 95.00 The type of load Fan & Pump Application The type of work style Light Duty ; Normal Duty Built-in PLC Yes Support external power supply card Yes No. 1 slot card Yes Slot 2 card No No. 3 slot card Digital IO Card ; Relay Card ; Analog IO Card ; External Power Supply Card Minimum Carrier Frequency (kHz) 2 Maximum Carrier Frequency (kHz) 15 Maximum Output Frequency (Hz) 599.00 Drive type Single Drive Type of inverter module Single Axis Rectifier module type Not Applicable Component type Inverter Module The inverter module is driven into the voltage Not Applicable Built-in motor Not Applicable

Description

Delta VFD185CP43B-21 is a fan and pump dedicated inverter from the CP2000 series, optimized for energy-saving operation in various fluid systems with three-phase 380–460V input and 18.5kW rated output power. It features an energy-saving control mode that adjusts motor speed according to actual system demand (pressure/flow/temperature), significantly reducing power consumption compared to traditional throttle control methods. The inverter integrates a PID controller with auto-tuning function, enabling automatic regulation of system parameters to maintain stable operation, and supports advanced functions such as sleep/wake control (to save energy during low-demand periods), pump rotation control (to prevent pump jamming), and dry-running protection (to avoid pump damage). It provides a wide output frequency range (0.1–600Hz), soft start/stop function (0.1–300s acceleration/deceleration time), and multiple control modes (local, remote, communication). Comprehensive protection functions include overcurrent, overvoltage, undervoltage, overload (120% for 60s), overheating, phase loss, short circuit, and motor thermal protection. With its user-friendly design (detachable control panel, real-time parameter display), high efficiency (>95%), and reliable performance, this inverter is widely applied in water supply, drainage, HVAC, and ventilation systems to improve energy efficiency and reduce operational costs.
Unsubscribe

Discount Code

Subscribe
Please check the item(s) you are interested in. (required)

Enter email to obtain information:

Verification code:

verify-code
USE : 0.011425018310547